Picture | Mfr Part # | QUANTITY | Inventory | MANUFACTURE | Description | Package | Series | Part Status | Voltage - Rated | Operating Temperature | Approvals | Ingress Protection | Termination | Size / Dimension | Features | Width | Weight | Power (Watts) | Air Flow | Static Pressure | Bearing Type | Fan Type | Noise | RPM | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GLOBAL STOCKS | |||||||||||||||||||||||||
VIEW |
1,376
In-stock
|
Sanyo Denki America Inc. | DC AXIAL FAN 92X92X25MM TACH | San Ace 92 | Active | 24VDC | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | - | 3 Wire Leads | Square - 92mm L x 92mm H | Locked Rotor Protection, Speed Sensor (Tach) | 25.00mm | - | 2.16W | 44.5 CFM (1.25m³/min) | 0.120 in H2O (29.9 Pa) | Ball | Tubeaxial | 27.0 dB(A) | 2650 RPM | ||||
VIEW |
2,067
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM | San Ace 160 | Active | 24VDC | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UL | - | 2 Wire Leads | Square/Rounded - 160mm L x 160mm H | - | 40.00mm | 1.3 lbs (589.7g) | 7.44W | 44.5 CFM (1.25m³/min) | 0.629 in H2O (156.7 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
1,961
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM | San Ace 160 | Active | 12VDC | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | - | 2 Wire Leads | Square/Rounded - 160mm L x 160mm H | - | 40.00mm | 1.3 lbs (589.7g) | 7.68W | 44.5 CFM (1.25m³/min) | 0.629 in H2O (156.7 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
3,339
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM TACH | San Ace B160 | Active | 24VDC | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | - | 3 Wire Leads | Square/Rounded - 160mm L x 160mm H | Speed Sensor (Tach) | 40.00mm | 1.3 lbs (589.7g) | 7.44W | 44.5 CFM (1.25m³/min) | 0.629 in H2O (156.7 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
2,989
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM TACH | San Ace B160 | Active | 12VDC | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | - | 3 Wire Leads | Square/Rounded - 160mm L x 160mm H | Speed Sensor (Tach) | 40.00mm | 1.3 lbs (589.7g) | 7.68W | 44.5 CFM (1.25m³/min) | 0.629 in H2O (156.7 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
1,703
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM LOCK | San Ace 160 | Active | 24VDC | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UL | - | 3 Wire Leads | Square/Rounded - 160mm L x 160mm H | - | 40.00mm | 1.3 lbs (589.7g) | 7.44W | 44.5 CFM (1.25m³/min) | 0.629 in H2O (156.7 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
1,993
In-stock
|
Sanyo Denki America Inc. | AC AXIAL 160X40MM LOCK | San Ace 160 | Active | 12VDC | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UL | - | 3 Wire Leads | Square/Rounded - 160mm L x 160mm H | Locked Rotor Sensor | 40.00mm | 1.3 lbs (589.7g) | 7.68W | 44.5 CFM (1.25m³/min) | 1.259 in H2O (313.6 Pa) | Ball | Blower | 50.0 dB(A) | 1800 RPM | ||||
VIEW |
2,838
In-stock
|
Mechatronics Fan Group | FAN AXIAL 60X38MM 24VDC WIRE | MQ6038 | Active | 24VDC | - | CE, cUL, TUV, UL | - | 2 Wire Leads | Square - 60mm L x 60mm H | - | 38.00mm | 0.234 lb (106.14g) | - | 44.5 CFM (1.25m³/min) | 0.910 in H2O (226.7 Pa) | Ball | Tubeaxial | 53.0 dB(A) | 8000 RPM | ||||
VIEW |
2,771
In-stock
|
Sanyo Denki America Inc. | FAN 60X25MM 24VDC RBLS TACH, PWM | San Ace 60T | Active | 24VDC | -40 ~ 185°F (-40 ~ 85°C) | CSA, TUV, UL | - | 4 Wire Leads | Square - 60mm L x 60mm H | PWM Control, Speed Sensor (Tach) | 25.00mm | 0.22 lb (99.79g) | 6.72W | 44.5 CFM (1.25m³/min) | 0.976 in H2O (243.0 Pa) | Ball | Tubeaxial | 52.0 dB(A) | 10000 RPM | ||||
VIEW |
1,497
In-stock
|
Sanyo Denki America Inc. | FAN 60X25MM 12VDC RBLS TACH, PWM | San Ace 60T | Active | 12VDC | -40 ~ 185°F (-40 ~ 85°C) | CSA, TUV, UL | - | 4 Wire Leads | Square - 60mm L x 60mm H | PWM Control, Speed Sensor (Tach) | 25.00mm | 0.22 lb (99.79g) | 6.72W | 44.5 CFM (1.25m³/min) | 0.976 in H2O (243.0 Pa) | Ball | Tubeaxial | 52.0 dB(A) | 10000 RPM |